• prduct1

Products

Hot New Products Loop Calibrator - ET2110 High-Precision Temperature Process Calibrator – Zhongchuang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With state-of-the-art technologies and facilities, strict good quality regulate, reasonable cost, exceptional assistance and close co-operation with prospects, we're devoted to supplying the top benefit for our customers for Dry Bath Calibrator, Forehead Thermometer Infrared Calibrator, Laboratory Dc Power Supply, Customer satisfaction is our main goal. We welcome you to establish business relation with us. For further information, please don't hesitate to contact with us.
Hot New Products Loop Calibrator - ET2110 High-Precision Temperature Process Calibrator – Zhongchuang Detail:

1

¤ Measurement/output: voltage, millivolt, resistance, resistance, thermocouple, rtd, current, etc

¤ 220V measurement function

¤ Simulating 2-wire transmitter

¤ Resistance measurement options: 2 wires, 3 wires, 4 wires

¤ Accuracy: 0.01%, 0.02%

¤ Two isolated channels support measure and output simultaneously

¤ Providing manual step, automatic step, automatic step and manual step functions.

¤ 3.5 TFT LCD screen,resolution rate 480*320

¤ Measurement and output data can be displayed simultaneously or separately;

¤ 5000mAh Lithium battery

¤ Automatic power shutdown function, shutdown time can be set, and suitable for on-site use

¤ Providing DC 24V loop power for on -site use

¤ Thermocouple measurement and output provide three kinds of cold junction temperature compensation methods: built-in, external and manual, among them, external reference junction adopts A class Pt100 Platinum resistance, which can correct temperature through inputting certificate value

¤ Thermocouple types: R,S,K,E,J,T,N,B,L,U,XK,WRE325,WRE526;

¤ RTDtypes:PT100-385,PT100-392,PT100-JIS,PT200-385,PT500-385,PT1000-385,Cu10,Cu50,Cu100,Nil20,BA1,BA2,PT10;

¤ Temperature difference measurement function: the accuracy is up to 0.003℃. This product can measure the temperature difference between two points in the space, and complete a temperature difference data collection within 0.4 seconds, effectively improving the measurement accuracy.The 10-minute fluctuation during the test can be calculated in real time.Before using standard platinum resistance or standard thermocouple for measuring work, the measurement results can be traced through the input of certificate value, and meet the requirements of the thermostatic tank test specification for electrical measuring instruments.

¤ Standard temperature measurement function: Comparing with common thermocouple measurement and RTD measurement,the difference is that  this measurement method can trace the temperature by certificate value,the supported standard thremocouple and RTD are as followed: S、R、B、T, Pt25、Pt100 

¤ Arbitrary sensor’s measurement function; Users can transform the measured physical quantity(Pressure, flow speed, temperature,etc) to voltage, current, resistance,etc conveniently for measurement. Besides, Users only need to input the response curve in advance, and the multimeter will adopt the internal algorithm for numerical conversion and correction, and finally the measured physical quantity will be displayed on the screen.You are free to edit and modify the display units of the measured physical quantities.

¤ Precision temperature control function; Precision temperature control function will realize the temperature closed-loop control of thermostatic equipment, which replace the high precision PID controller.Under the condition of thermostatic equipment and network voltage,temperature fluctuation will be better than 0.02℃/10min (Thermostatic Bath)

¤ Measurement function of ρ’s value: can measure duty ratio of periodic square wave signal; verify and calibrate the PID parameter of Various digital temperature indicating regulators which is outputted by time scale,and conform to the requirement of 《JJG617-1996 digital temperature indicating regulators》

¤ Thermal Conversion Function: realize the conversion between various electric quantity and temperature.The types of electric quantity and temperature conversion include: working thermocouple, industrial rtd and various temperature transmitter.

¤ Numerical setting mode:its with the most flexible and convenient way to set output value; User can use the numerical keyboard to set output value directly, and can realize the incremental setting by direction key. In addition, the equipment also has a step or ramp numerical setting mode that can be numbered.

¤ Sinusoidal output function: The verification/calibration of some process logger (especially mechanical logger); Usually It involves running test, and it can provide signals to the measured table by using sinusoidal output mode.

¤ Data Record Function:  with powerful record management function, it can establish up to 32 device numbers. Each device number has 16 record pages, and each record page contains four basic information: time, measured value, output value and custom value.Users can carry out equipment management, record deletion and other operations according to requirements.

      Model

Accuracy

Temp Range

Optional Function

ET2110B

0.01级

15~25℃

For optional function,please contact us for detail code information about its relevant function

ET2110C

0.02级

ET2110BT

0.01级

0~50℃

ET2110CT

0.02级

Function

Range

Resolution rate(0.01%)

Resolution rate(0.02%)

Accuracy(0.01%)

Accuracy(0.02%)

Note

DC Output

Voltage

100mV

0.1µV

1µV

0.005%+0.003%

0.01%+0.005%

Max load current    <=2.5mA

1V

1µV

10µV

0.005%+0.001%

0.01%+0.005%

10V

10µV

100µV

0.005%+0.001%

0.01%+0.005%

Current (Active/Passive)

30mA

0.1µA

1µA

0.005%+0.003%

0.01%+0.003%

Max load voltage(active output)   20V

Resistance

50Ω

0.1mΩ

0.005%+10 mΩ

0.01%+15 mΩ

Excitation current 0.4-4mA

500Ω

1mΩ

0.005%+20 mΩ

0.01%+30 mΩ

Excitation current  0.1-2mA

5000Ω

10mΩ

0.005%+50 mΩ

0.01%+50 mΩ

Excitation current 0.04-0.4mA

24V

24V

 

±10%

Loop output

RTD

See detail of RTD sheet

 

Thermocouple

See detail of thermocouple sheet

 

DC Measurement

Voltage

200mV

0.1µV

0.005%+0.003%

0.01%+0.005%

 

2V

1µV

0.005%+0.001%

0.01%+0.005%

 

20V

10µV

0.005%+0.001%

0.01%+0.005%

 

200V

100µV

0.005%+0.001%

0.01%+0.005%

 

Current

20mA

0.1µA

0.005%+0.003%

0.01%+0.003%

 

200mA

1µA

0.005%+0.003%

0.01%+0.003%

 

Resistance (4-wire)

50Ω

0.1mΩ

0.005%+10 mΩ

0.01%+15 mΩ

Excitation current  1mA

500Ω

1mΩ

0.005%+20 mΩ

0.01%+30 mΩ

5kΩ

10mΩ

0.005%+50 mΩ

0.01%+50 mΩ

Excitation current  0.1mA

Resistance (2,3-wire)

50Ω

0.1mΩ

0.005%+30 mΩ

(三线)

0.005%+50 mΩ

(二线)

0.005%+35 mΩ

(三线)

0.005%+60 mΩ

(二线)

Excitation current  1mA

500Ω

1mΩ

5kΩ

10mΩ

0.005%+80mΩ

0.01%+80 mΩ

Excitation current  0.1mA

RTD

See detail of RTD sheet

 

Thermocouple

See detail of thermocouple sheet

 

AC Measurement

AC Voltage

200mV

1µV

±(0.2%+100)(40Hz-30kHz)

 

2V

10µV

 

20V

100µV

±(0.2%+100)(40Hz-5kHz)

±(0.8%+300)(5k-30kHz)

 

200V

1mV

±(0.2%+200)(40Hz-5kHz)

±(0.8%+450)(5k-30kHz)

 

AC Current

20mA

0.1µA

±(0.3%+400)(40Hz-5kHz)

 

200mA

1µA

 

RTD Sheet

Signal Types

Temp Range

Resolution rate

Accuracy (0.01%)

Accuracy (0.02%)

Note

PT10

-200-850℃

0.01℃

0.1℃

0.2℃

4 -wire measurement

PT100-385

-200-850℃

0.01℃

0.1℃

0.2℃

PT100-392

-200-850℃

0.01℃

0.1℃

0.2℃

PT100-JIS

-200-850℃

0.01℃

0.1℃

0.2℃

PT200-385

-200-630℃

0.01℃

0.1℃

0.2℃

PT500-385

-200-630℃

0.01℃

0.2℃

0.3℃

PT1000-385

-200-650℃

0.01℃

0.1℃

0.2℃

Cu10

-100-260℃

0.01℃

0.5℃

0.6℃

Cu50

-50-150℃

0.01℃

0.15℃

0.25℃

Cu100

-50-150℃

0.01℃

0.08℃

0.2℃

BA1

-200-650℃

0.01℃

0.4℃

0.5℃

BA2

-200-650℃

0.01℃

0.25℃

0.3℃

Ni20

-80-260℃

0.01℃

0.3℃

0.4℃

Thermocouple Sheet

Signal Types

Temp Range

Resolution rate

Accuracy (0.01%)

Accuracy (0.02%)

Note

K

-200-0℃

0-1372℃

0.1℃

0.4℃

0.3℃

Exclude accuracy of cold junction compensation

R

-50-0℃

0-1768℃

0.1℃

0.9℃

0.7℃

S

-50-0℃

0-1768℃

0.1℃

0.9℃

0.6℃

E

-50-0℃

0-1000℃

0.1℃

0.5℃

0.4℃

J

-200-0℃

0-1200℃

0.1℃

0.2℃

0.1℃

T

-100-0℃

0-400℃

0.1℃

0.3℃

0.15℃

L

-200-900℃

0.1℃

0.2℃

N

-200-0℃

0-1300℃

0.1℃

0.3℃

0.2℃

B

600-1820℃

0.1℃

0.6℃

U

-200-0℃

0-400℃

0.1℃

0.4℃

0.2℃

XK

-200-800℃

0.1℃

0.5℃

WRE325

0-1500℃

0.1℃

0.5℃

WRE526

0-1500℃

0.1℃

0.4℃

Note: accuracy of built-in cold junction compensation is 0.5℃


Product detail pictures:

Hot New Products Loop Calibrator - ET2110 High-Precision Temperature Process Calibrator – Zhongchuang detail pictures


Related Product Guide:

We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for Hot New Products Loop Calibrator - ET2110 High-Precision Temperature Process Calibrator – Zhongchuang , The product will supply to all over the world, such as: Zurich, Sri Lanka, Bhutan, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Moira from Afghanistan - 2018.05.22 12:13
    We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Page from Finland - 2017.10.27 12:12
    Write your message here and send it to us