• prduct1

Products

Hot New Products Blackbody Furnace For Thermometer Calibration - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've got a highly efficient group to deal with inquiries from shoppers. Our purpose is "100% client fulfillment by our product high-quality, price tag & our staff service" and enjoy a superb reputation amongst clientele. With quite a few factories, we will provide a wide variety of Ac Dc Power Supply, Blackbody Calibration Furnace, Temperature Calibrator Oil Bath, We encourage you to make get hold of as we've been wanting for companions inside our venture. We are sure you'll uncover doing company with us not only fruitful but also profitable. We've been prepared to provide you with what you require.
Hot New Products Blackbody Furnace For Thermometer Calibration - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang Detail:

¤  Measurement/output: voltage, current, resistance, frequency, pulse, switching values, in which the current output supports active and passive;

¤  220V measurement function

¤  200mA AC current measurement function

¤  Simulating RTD and thermocouple through temperature form

¤  Simulating 2-wire transmitter

¤  Resistance measurement options: 2 wires, 3 wires, 4 wires

¤  Accuracy: 0.01%, 0.02%

¤  Two isolated channels support measure and output simultaneously

¤  Providing manual step, automatic step, automatic step and manual step functions.

¤  3.5 TFT LCD screen,resolution rate 480*320

¤  Measurement and output data can be displayed simultaneously or separately;

¤  5000mAh Lithium battery

¤  Automatic power shutdown function, shutdown time can be set, and suitable for on-site use

¤  DC 24V loop power for on -site use

¤  Thermocouple measurement and output provide three kinds of cold junction temperature compensation methods: built-in, external and manual, among them, external reference junction adopts A class Pt100 Platinum resistance, which can correct temperature through inputting certificate value

¤  Thermocouple types: R,S,K,E,J,T,N,B,L,U,XK,WRE325,WRE526;

¤  RTD 

types:PT100-385,PT100-392,PT100-JIS,PT200-385,PT500-385,PT1000-385,Cu10,Cu50,Cu100,Nil20,BA1,BA2,PT10;

¤ HART Function:completely replace HART communicator;set or calibrate smart transmitter’s range; force the output current of intelligent transmitter at fix value(20mA, 12mA, 4mA ) set linear or square function; Set up linear or square functions, which can HART reset the pressure sensor of transmitter, etc.;

¤ Pressure module function: through RS232 communication port, it can be used together with our COMPANY’s ET-CY series pressure module, for on-site verification of pressure transmitter, pressure switch, pressure gauge, blood pressure meter or other pressure instruments, and also for precise measurement of pressure;Support 12 pressure units: kPa, MPa, Pa, PSI, inHg, inH2O, mmHg, mmH2O, bar, Mbar, ATM, kg/cm2, etc.

¤ Temperature difference measurement function: the accuracy is up to 0.003℃. This product can measure the temperature difference between two points in the space, and complete a temperature difference data collection within 0.4 seconds, effectively improving the measurement accuracy.The 10-minute fluctuation during the test can be calculated in real time.Before using standard platinum resistance or standard thermocouple for measuring work, the measurement results can be traced through the input of certificate value, and meet the requirements of the thermostatic tank test specification for electrical measuring instruments.

¤ Standard temperature measurement function: Comparing with common thermocouple measurement and RTD measurement,the difference is that  this measurement method can trace the temperature by certificate value,the supported standard thremocouple and RTD are as followed: S、R、B、T,Pt25、Pt100 

¤ Arbitrary sensor’s measurement function; Users can transform the measured physical quantity(Pressure, flow speed, temperature,etc) to voltage, current, resistance,etc conveniently for measurement. Besides, Users only need to input the response curve in advance, and the multimeter will adopt the internal algorithm for numerical conversion and correction, and finally the measured physical quantity will be displayed on the screen.You are free to edit and modify the display units of the measured physical quantities.

¤ Precision temperature control function; Precision temperature control function will realize the temperature closed-loop control of thermostatic equipment, which replace the high precision PID controller.Under the condition of thermostatic equipment and network voltage,temperature fluctuation will be better than 0.02℃/10min (Thermostatic Bath)

Measurement function of ρ’s value: can measure duty ratio of periodic square wave signal; verify and calibrate the PID parameter of Various digital temperature indicating regulators which is outputted by time scale

¤ Thermal Conversion Function: realize the conversion between various electric quantity and temperature.The types of electric quantity and temperature conversion include: working thermocouple, industrial rtd and various temperature transmitter.

¤ Numerical setting mode:its with the most flexible and convenient way to set output value; User can use the numerical keyboard to set output value directly, and can realize the incremental setting by direction key.In addition, the equipment also has a step or ramp numerical setting mode that can be numbered.

¤ Sinusoidal output function: The verification/calibration of some process logger (especially mechanical logger); Usually It involves running test, and it can provide signals to the measured table by using sinusoidal output mode.

¤ Data Record Function:  with powerful record management function, it can establish up to 32 device numbers. Each device number has 16 record pages, and each record page contains four basic information: time, measured value, output value and custom value.Users can carry out equipment management, record deletion and other operations according to requirements.

Model

Accuracy

Temp Range

Optional function

ET2125B

0.01%

15~25℃

For optional function,please contact us for detail code information about its relevant function

ET2125C

0.02%

ET2125BT

0.01%

0~50℃

ET2125CT

0.02%

Function

Range

Resolution rate(0.01%)

Resolution rate(0.02%)

Accuracy(0.01%)

Accuracy(0.02%)

Note

DC Output

Voltage

100mV

0.1µV

1µV

0.005%+0.003%

0.01%+0.005%

Max load current <=2.5mA

1V

1µV

10µV

0.005%+0.001%

0.01%+0.005%

10V

10µV

100µV

0.005%+0.001%

0.01%+0.005%

Current (Active/Passive)

30mA

0.1µA

1µA

0.005%+0.003%

0.01%+0.003%

Max load voltage(active output)20V

Resistance

50Ω

0.1mΩ

0.005%+10 mΩ

0.01%+15 mΩ

Excitation current 0.4-4mA

500Ω

1mΩ

0.005%+20 mΩ

0.01%+30 mΩ

Excitation current 0.1-2mA

5000Ω

10mΩ

0.005%+50 mΩ

0.01%+50 mΩ

Excitation current 0.04-0.4mA

24V

24V

 

±10%

Loop output

Frequency

10Hz

0.001Hz

0.01%FS

Max load current    ≤2.5mA

1kHz

0.01Hz

100kHz

10Hz

 

10Hz(1~100000)

1cyc

±2dig

Max load current    ≤2.5mA

1kHz(1~100000)

100kHz(1~100000)

Switch value

100Hz(1Hz~110Hz)

0.01Hz

±2dig

 

1kHz(0.1kHz~1.1kHz)

1Hz

 

10kHz(1kHz~11kHz)

0.1KHz

 

100KHz(10kHz~110kHz)

2KHz

 

RTD

See detail of RTD sheet

 

Thermocouple

See detail of thermocouple  sheet

 

DC Measurement

Voltage

200mV

0.1µV

0.005%+0.003%

0.01%+0.005%

 

2V

1µV

0.005%+0.001%

0.01%+0.005%

 

20V

10µV

0.005%+0.001%

0.01%+0.005%

 

200V

100µV

0.005%+0.001%

0.01%+0.005%

 

Current

20mA

0.1µA

0.005%+0.003%

0.01%+0.003%

 

200mA

1µA

0.005%+0.003%

0.01%+0.003%

 

Resistance (4-wire)

50Ω

0.1mΩ

0.005%+10 mΩ

0.01%+15 mΩ

Excitation current 1mA

500Ω

1mΩ

0.005%+20 mΩ

0.01%+30 mΩ

5kΩ

10mΩ

0.005%+50 mΩ

0.01%+50 mΩ

Excitation current 0.1mA

Resistance (2,3-wire)

50Ω

0.1mΩ

0.005%+30 mΩ

(3-wire)

0.005%+50 mΩ

(2-wire)

0.005%+35 mΩ

(3-wire)

0.005%+60 mΩ

(2-wire)

Excitation current 1mA

500Ω

1mΩ

5kΩ

10mΩ

0.005%+80mΩ

0.01%+80 mΩ

Excitation current 0.1mA

RTD

See detail of RTD sheet

 

Thermocouple

See detail of thermocouple  sheet

 

Switch measurement

 

 

CLOSE/OPEN

Excitation current 1mA

Frequency

10Hz

0.001Hz

0.01%FS

 

1kHz

0.01Hz

 

100kHz

10Hz

 

AC Measurement

AC Voltage

200mV

1µV

±(0.2%+100)(40Hz-30kHz)

 

2V

10µV

 

20V

100µV

±(0.2%+100)(40Hz-5kHz)

±(0.8%+300)(5k-30kHz)

 

200V

1mV

±(0.2%+200)(40Hz-5kHz)

±(0.8%+450)(5k-30kHz)

 

AC Current

20mA

0.1µA

±(0.3%+400)(40Hz-5kHz)

 

200mA

1µA

 

Product detail pictures:

Hot New Products Blackbody Furnace For Thermometer Calibration - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang detail pictures


Related Product Guide:

With dependable high quality approach, great reputation and excellent customer support, the series of products and solutions produced by our firm are exported to lots of countries and regions for Hot New Products Blackbody Furnace For Thermometer Calibration - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang , The product will supply to all over the world, such as: Mumbai, Turkmenistan, Angola, We hope to have long-term cooperation relationships with our clients. If you are interested in any of our products, please do not hesitate to send enquiry to us/company name. We ensure that you can be totally satisfied with our best solutions!
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Elaine from Finland - 2018.05.13 17:00
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Diego from Angola - 2017.04.28 15:45
    Write your message here and send it to us