With dependable high quality approach, great reputation and excellent customer support, the series of products and solutions produced by our firm are exported to lots of countries and regions for Multimeter With Capacitance, Thermostatic Bath, Process Calibrator, We are looking forward to receiving your enquiries soon.
ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang Detail:

¤ The highest measuring frequency is 100kHz, and the stepping; frequency is continuously adjustable at 1Hz;

¤ Test level 10~2000 mV, 1 mV step continuously adjustable;

¤ Supporting DC Resistance (DCR) and Electrolytic Capacitance Measurement;

¤ Internal bias voltage output 10mV~1500mV;

¤ 3.5-inch TFT display, 5-bit display;

¤ Data recording function (maximum, minimum, average);

¤ Supporting SCPI Communication Protocol;

¤ Provide system settings to configure Chinese or English, buzzer, screen brightness, etc;

¤ The basic measurement accuracy is 0.2%;

¤ Manual and automatic range;

¤ With open circuit and short circuit calibration function;

¤ Comparator sorting (5 gears), alarm function. 

Model

ET1090A

ET1090B

ET1090C

ET1091A

ET1091B

ET1091C

Testing frequency

10 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K)

12 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K)

16 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K, 40K, 50K, 80K, 100K)

10-10KHz continuous adjustable, 1Hz stepby-step

10-10KHz

continuous

adjustable, 1Hz stepby-step

10-100KHz

continuous

adjustable, 1Hz step by-step

Display screen

Display screen 3.5 inch TFT LCD

Number of display digits

Principal parameter: 5 digit,Secondary parameter: 5 digit

Measured parameter

Principal parameter: L/C/R/Z,Secondary parameter: X/D/Q/θ/ESR

Measurement Range

L:0.001μH~9999H

C:0.001pF~99.999mF

R:0.0001Ω~99.99MΩ

Basic accuracy

0.20%

Measuring display speed

2 time/s (slow), 4 times/s (medium), 8 time/s (fast)

Internal bias

0-1500mV adjustable, at a step of 1mV.

Testing level

Six fixed level(0.1V、0.3V、0.6V、1V、1.5V、2V)

0.1~2V adjustable, at a step of 1mV.

Signal source output

impedance

30Ω、100Ω

Calibration function

Open circuit calibration, short circuit calibration

Screening function

The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%.

Comparator

5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting

Interfaces

standard: RS232(or 485), USB Device, Handler ;optional: GPIB,USB Host

Others

Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional

¤ Power supply voltage: 220V.AC±10%, or 110V.AC±10%, 45~65Hz;

¤ Power consumption: <10W;

¤ Display: 3.5 inch TFT LCD screen, resolution 480 *320, color 16M;

¤ Temperature range: Operating state 10℃~+40℃, non-operating state -10℃ ~+60℃;

¤ Humidity range: 0 ~ 40 C, < 90% relative humidity;

¤ Interface: RS232 (or 485), USB Device, Handle, GPIB, USB Host. 

¤ Three core power cord(30A51)

¤ 4-terminals of kelvin testing cable(35A51) 

ET1090ET1091 Benchtop LCR Meter for Component Measurement 1
ET1090ET1091 Benchtop LCR Meter for Component Measurement 2
ET1090ET1091 Benchtop LCR Meter for Component Measurement 3
ET1090ET1091 Benchtop LCR Meter for Component Measurement 4


Product detail pictures:

ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures


Related Product Guide:

Innovation, excellent and reliability are the core values of our company. These principles today much more than ever form the basis of our success as an internationally active mid-size business for ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang , The product will supply to all over the world, such as: Niger, Cambodia, Detroit, We are in continuous service to our growing local and international clients. We aim to be worldwide leader in this industry and with this mind; it is our great pleasure to serve and bringing the highest satisfaction rates among the growing market.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Frances from Istanbul - 2018.09.21 11:01
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Liz from Malta - 2017.04.18 16:45
    Write your message here and send it to us