• prduct1

Products

China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for Loop Calibrator 4-20ma, Voltmeter Multimeter, High Frequency Current Measurement, We welcome new and aged buyers from all walks of daily life to get hold of us for upcoming business enterprise interactions and acquiring mutual good results!
China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang Detail:

¤ Clear graphic interface with 5.0 inches 800x480TFT touch screen  ; adjustable brightness

¤ Support English and Chinese; Real-time clock display

¤ Support mV measurement, measurement range -78mV~78mV 

¤ Support2 wires/ 4 wires resistance measurement, measurement range: 0~1600Ω

¤ Supporting RTD measurement,including standard Pt100, Pt25 and conventional Pt100, Pt25,Pt50,Pt200,Pt500,Pt1000,Pt100-392,Pt100-JIS,Cu10,Cu50,Cu100,Ni120. Users can define name of sensor’s type by their own.

¤ Support TC measurement, including standard S-type thermocouple, and conventional S、R、K、J、B、T、E、N、L、U、XK、BP. Users can define name of sensor’s type by their own.(ET3131和3132 don’t support this function)

¤ Standard Pt100, Pt25 and S-type thermocpuple, each can store 5 sets of probe parameter . (ET3131和3132 don’t support standard S-type thermocouple)

¤ Provide communication port: RS485 and USB Device 

Power Supply:AC 110/220V,50~60Hz。

Power:<10W。

Display:5 -inches TFTLCD touch screen ,resolution rate 800×480,color 16M 。

Dimension :350mm×340mm×55mm (L×W×H)。

Communication port :RS485and USB

1

Model

ET3131

ET3132

ET3131B

ET3132B

Channels

Single Channel

Double Channels

Single Channel

Double Channels

Resistance Measurement

Highest Resolution

10μΩ

10μΩ

 Measurement Range

0~1600Ω

0~1600Ω

Accuracy (only including Meter’s accuracy )

±(0.003%+50)

±(0.003%+50)

RTD Measurement

Highest Resolution

0.0001℃

0.0001℃

 Measurement Range

-200~850℃

-200~850℃

Accuracy (only including Meter’s accuracy )

±0.004℃@–100℃   ±0.006℃@0℃±0.009℃@100℃   ±0.012℃@200℃

±0.018℃@400℃ ±0.024℃@600℃

±0.004℃@–100℃   ±0.006℃@0℃±0.009℃@100℃   ±0.012℃@200℃

±0.018℃@400℃ ±0.024℃@600℃

mV Measurement

Highest Resolution

10nV

 Measurement Range

-78mV~+78mV

Accuracy (only including Meter’s accuracy ))

±(0.0018%+30)

Thermocouple Measurement

Highest Resolution

0.001℃

 Measurement Range

-250~2500℃

Accuracy (only including Meter’s accuracy )

S:±0.5℃ R:±0.4℃ K:±0.15℃  J:±0.1℃B:±0.6℃ T:±0.1℃  E:±0.1℃    N:±0.15℃

L:±0.15℃  U:±0.15℃  XK:±0.1℃  BP:±0.5℃

 Current Measurement

Highest Resolution

1nA

 Measurement Range

-24mA~24mA

Accuracy (only including Meter’s accuracy )

±(0.04%+20)

Other Functions

 Resistance Measurement

  Supporting 2 wires/ 4 wires

RTD Measurement

Supporting 3wires/ 4 wires

RTD Sensor’s type

Supporting conventional sensor types: Pt10、Pt25、Pt50、Pt100、Pt200、Pt500、Pt1000、Pt100-392、Pt100-JIS、Cu10、Cu50、Cu100、Ni120 and 2 standard sensors’ type : Pt25、Pt100, Users can define name of sensor’s type by their own. 

Thermocouple’s Cold Junction (only support ET3131 Band 3132B)

The temperature of cold junction can be adjusted automatically or by manual

Thermocouple’s type (only support ET3131 Band 3132B)

Supporting conventional thermocouples:S、R、K、J、B、T、E、N、L、U、XK、BP and 1 standard S-type thermocouple Users can define name of sensor’s type by their own.

 Temperature Curve Display

Support temperature curve display;Save 10 sets of historical data and curves;Read historical data and curves

Temperature Unit

℃、℉、K

Display Screen

5 -inches TFTLCD touch screen ,resolution rate 800×480,color 16M

Communication Port

Supporting RS485 and USB 

Attn 1: Standard Pt25 and standard Pt100 Platinum RTD only supports 4 wires measurement.

Attn 2:The temperature measuring range is limited by the display range of the instrument .

The temperature using range of the actual thermal resistance and thermocouple depends on the specific sensor types

Standard Accessories:

two-headed 4mm Banana Plug’s wiring 50cm* 2

Power Line *1

User Manual *1

Optional Accessories:

RS485Communication Line

USB Communication Line


Product detail pictures:

China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang detail pictures

China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang detail pictures

China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang detail pictures


Related Product Guide:

Our growth depends around the superior machines, exceptional talents and consistently strengthened technology forces for China wholesale Dry Well Calibrator - ET3131 Series High-Precision Bench Thermometer – Zhongchuang , The product will supply to all over the world, such as: Greek, Durban, Pakistan, Our company regards "reasonable prices, high quality,efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits in future. Welcome to contact us.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Miguel from Lahore - 2018.09.29 17:23
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Jodie from Roman - 2018.11.28 16:25
    Write your message here and send it to us